SV Industrial
VentilatorsWind-driven roof ventilation

Natural ventilation for factories, warehouses and industrial buildings. Ampelair Straight Vane ventilators exhaust hot, stale air using wind power, with throat sizes from 150mm to 950mm.

Ampelair Straight Vane industrial roof ventilator with a square-to-round base
Wind poweredNo electricity for the rotary head
150–950 mm throatsSix industrial model sizes
Australian madeAustralian owned and manufactured

Natural airflow for industrial buildings

As wind turns the ventilator head, air is exhausted through the straight vanes and replacement air enters the building through suitable inlet openings.

The aluminium head, enclosed bearing assembly and choice of base configurations suit new installations and replacement requirements. Heads and bases can be supplied together or ordered separately.

Help release trapped heat

Draw hot air out of the building or roof space to support more comfortable working conditions.

Support fresh air circulation

Combine roof exhaust with suitable inlet openings to encourage natural airflow through the space.

Rows of Ampelair SV ventilators installed across a large industrial metal roof

Built for industrial roof ventilation

No rotary-head running costs

Wind-driven extraction operates without a mains electrical connection to the ventilator head.

Enclosed stainless steel bearings

Self-lubricating bearings in a double-row stainless steel casing support low-friction rotation.

Aluminium construction

Aluminium ventilator heads provide corrosion resistance and a durable, lightweight assembly.

Protected shaft assembly

A two-part shaft uses an anti-corrosive steel axle enclosed in a fire-resistant nylon casing to maintain alignment.

Straight vane design

Free-flowing vanes combine an optimised angle and broad surface area for natural air extraction.

Flexible base options

Choose a square-to-round base or a variable-pitch base for supported models, with head-only supply also available.

Sizes and specifications

Scroll horizontally to view all specifications.

SV ventilator head dimensions
ModelThroat diameterHead widthHead heightSquare-to-round baseVariable-pitch baseRoof pitch*
SV300300 mm480 mm380 mmAvailableAvailable1°–40°
SV450450 mm625 mm405 mmAvailableAvailable1°–30°
SV600600 mm770 mm450 mmAvailableAvailable1°–22.5°
SV800800 mm985 mm535 mmAvailable—1°–22.5°
SV950950 mm1130 mm575 mmAvailable—1°–22.5°

Bases, finishes and damper options

Square-to-round base

A heavy-duty Zincalume® base supplied with a roof tray. Roof pitch and profile must be specified when ordering.

SV150 · SV300 · SV450 · SV600 · SV800 · SV950

Variable-pitch base

An aluminium variable-pitch base and flashing, available for selected models within their listed pitch limits.

SV300 · SV450 · SV600

Natural or colour finish

Aluminium heads are available in mill finish or powder-coated colours to match steel roofing. Specify the required base finish and colour when ordering.

Confirm colour and availability with Ampelite.

Optional butterfly dampers

Manual or electric single-disc butterfly dampers provide control of air movement. Available in 300mm, 450mm, 600mm, 800mm and 950mm sizes for square-to-round bases only.

Electric dampers must be fitted by a qualified electrician. The ventilator head itself remains wind driven.

Factory volume diagram showing the roof space above the ceiling and the building space below

Select the size and number of ventilators

Confirm the model, quantity and layout with Ampelite using the requirements of your building.

  • Building or roof space volume and required air changes.
  • Effective stack height from the air intake to the ventilator base.
  • Typical wind speed and inside-to-outside temperature difference.

Where the occupied space is air conditioned, the brochure bases roof ventilation on the roof space volume and advises against drawing air from below the ceiling.

Installation requirements

Roof and support requirements

  • Specify the roof pitch and sheet profile when ordering the base.
  • Follow Ampelair's fixing instructions for roof trays, flashing and base installation.
  • For SV600 and larger units, the brochure recommends solid support between purlins. Correct support is a condition of warranty.
  • Plan replacement-air openings and ventilator placement together to support effective airflow.
  • Have any electric damper installed by a qualified electrician.

View installation guidance

Installers fitting an Ampelair SV ventilator on an industrial metal roof
Follow the fixing and support requirements for the selected model and base.

15-year warranty

Coverage and conditions

Ampelite's published SV warranty covers defects in materials or workmanship that cause the industrial ventilator to stop rotating, for 15 years.

Failures caused by incorrect installation, unauthorised attempted repair, accident or an act of God are excluded. The brochure also requires correct support for larger units and states that written project warranties follow verification of installation procedures.

These benefits are additional to rights under Australian Consumer Law. Contact your local Ampelite office for full terms and claim procedures.

Product brochure

Ampelair SV Industrial Ventilators

Models, dimensions, base options, capacity tables and installation guidance · PDF · 4 pages

Open PDF

Before you choose an SV ventilator

Does the ventilator need electricity?

No. The rotary ventilator head uses wind power. If an electric butterfly damper is specified, that accessory needs electrical installation by a qualified electrician.

Which throat sizes are available?

The SV range includes 150mm, 300mm, 450mm, 600mm, 800mm and 950mm throat sizes. Selection depends on the building volume, ventilation target and operating conditions.

Can I order a replacement head without a base?

Yes. Heads and bases can be supplied separately. Confirm the existing throat size, base and installation requirements with Ampelite when selecting a replacement.

Which models have variable-pitch bases?

The brochure lists variable-pitch aluminium bases for SV300, SV450 and SV600. Square-to-round bases are listed for all six models.

Can airflow be controlled with a damper?

Manual and electric butterfly dampers are available for square-to-round bases in 300mm, 450mm, 600mm, 800mm and 950mm sizes. Confirm the required operation and electrical requirements when ordering.

How do I work out the required quantity?

Start with the building or roof space volume, target air changes, stack height, wind speed and temperature difference. The brochure provides initial guidance; Ampelite can assist with the final selection and layout.

Plan your industrial roof ventilation

Contact Ampelite